Cable size calculator

Two calculators on one page. Size a motor circuit from kW or hp, or any circuit from amps, kW or kVA. You get the cable, voltage drop, earth size and, if you enter the breaker, the earth fault loop and fault checks, in plain language, with a PDF summary to share.

For estimating purposes only. Results are indicative. Final selections must be confirmed by a qualified person for the actual installation and conditions.

FreeNo loginNo watermark

1  The load

Starting method

2  The cable

3  Installation and run

4  Protection optional

The MCB sets the earth fault loop length check (loop impedance at 80% of nominal voltage). Fault level and clearing time set the short-circuit check.

Results are indicative estimates for planning only and must be checked by a qualified person. Read the calculator disclaimer.

How the calculator works

Two calculators, one method. Pick Motor circuit to start from kW or hp, or General circuit to start from amps, kW or kVA.

1. Load current. Motor circuits use the typical full-load current of a 4-pole motor at the selected voltage, or your nameplate figure, with an optional 25% margin. Star-delta splits it across two cables at 58% each. General circuits use the amps you enter, or work them out from kW and power factor, or kVA.

2. Current-carrying capacity (heat balance). The rating is worked out from the conductor’s losses (I²R at operating temperature) against the thermal resistance of the insulation, sheath and surroundings for the installation method, at the ambient you enter, then reduced for grouping and compared with the design current. Parallel cables share the load and count toward grouping.

Voltage drop % = mV/A/m × I × L ÷ 1000 ÷ V × 100

3. Voltage drop (resistance and reactance at operating temperature, 5% limit per AS/NZS 3000). Checked against your limit, 5% by default. If it fails, the next size up is tried and the tool tells you voltage drop set the size.

4. Protection (optional). With an MCB entered, the tool checks IB ≤ IN ≤ IZ and the maximum route length for automatic disconnection from the loop impedance at 80% of nominal voltage. With a fault level and clearing time, it checks the active conductor can survive the fault (S ≥ I√t ÷ k).

Lmax = 0.8 × Uo × Sph × Spe ÷ (ρ × Ia × (Sph + Spe))

5. Earth conductor. Full size up to 16 mm², then at least one-third of the active size, rounded up to a standard size.

The smallest cable that passes every check is picked, and the sizes either side are shown so you can see why. Ratings are calculated from first principles for estimating purposes only.

Common questions

How does this cable calculator work?

It works from first principles: conductor resistance at operating temperature, a heat-balance current rating for the installation method with ambient temperature and grouping, voltage drop from resistance and reactance against the 5% limit in AS/NZS 3000, protection coordination, earth size, earth fault loop length and the adiabatic short-circuit check. It is for estimating purposes only, so a licensed electrician must confirm the final design.

What supply voltages does it use?

230 V and 240 V single-phase, and 400 V and 415 V three-phase. 230/400 V is the nominal voltage in AS 60038; many sites and nameplates still quote 240/415 V.

What voltage drop is allowed?

AS/NZS 3000 allows 5% from the point of supply to the load. If the submains already use some of that, set a lower limit for the final circuit.

When should a cable run be professionally designed?

Long runs, large motors, large VSDs, high temperatures, grouped underground cables, high fault levels, or anywhere discrimination and protection settings matter. The tool flags these.