Class 10.9 bolt torque chart
Tightening torque for grade 10.9 metric coarse bolts at 75% of proof load. 10.9 bolts are about 40% stronger than 8.8, so never swap one for the other without checking the joint.
For estimating purposes only. Results are indicative. Final selections must be confirmed by a qualified person for the actual installation and conditions.
Torque figures are for coarse-thread metric bolts with a matching nut and hardened washer. Use the equipment maker’s figure where one is given.
| Size | Torque Nm | Torque ft-lb | Preload kN |
|---|---|---|---|
| M6 | 14 | 10 | 12.5 |
| M8 | 33 | 24 | 22.8 |
| M10 | 65 | 48 | 36.1 |
| M12 | 113 | 84 | 52.5 |
| M14 | 180 | 133 | 71.6 |
| M16 | 281 | 208 | 97.7 |
| M18 | 387 | 286 | 119.5 |
| M20 | 549 | 405 | 152.5 |
| M22 | 747 | 551 | 188.6 |
| M24 | 949 | 700 | 219.7 |
| M27 | 1,389 | 1,024 | 285.7 |
| M30 | 1,886 | 1,391 | 349.2 |
| M33 | 2,566 | 1,893 | 432.0 |
| M36 | 3,296 | 2,431 | 508.6 |
| M42 | 5,276 | 3,891 | 697.8 |
| M48 | 7,922 | 5,843 | 916.9 |
Results are indicative estimates for planning only and must be checked by a qualified person. Read the calculator disclaimer.
Grade 10.9 torque by thread condition
| Size | Black or plain, lightly oiled (K 0.18) | Plain, dry (K 0.2) | Zinc plated, dry (K 0.2) | Moly or anti-seize paste (K 0.12) | Preload kN |
|---|---|---|---|---|---|
| M6 | 14 | 15 | 15 | 9 | 12.5 |
| M8 | 33 | 36 | 36 | 22 | 22.8 |
| M10 | 65 | 72 | 72 | 43 | 36.1 |
| M12 | 113 | 126 | 126 | 76 | 52.5 |
| M14 | 180 | 200 | 200 | 120 | 71.6 |
| M16 | 281 | 313 | 313 | 188 | 97.7 |
| M18 | 387 | 430 | 430 | 258 | 119.5 |
| M20 | 549 | 610 | 610 | 366 | 152.5 |
| M22 | 747 | 830 | 830 | 498 | 188.6 |
| M24 | 949 | 1,055 | 1,055 | 633 | 219.7 |
| M27 | 1,389 | 1,543 | 1,543 | 926 | 285.7 |
| M30 | 1,886 | 2,095 | 2,095 | 1,257 | 349.2 |
| M33 | 2,566 | 2,851 | 2,851 | 1,711 | 432.0 |
| M36 | 3,296 | 3,662 | 3,662 | 2,197 | 508.6 |
| M42 | 5,276 | 5,862 | 5,862 | 3,517 | 697.8 |
| M48 | 7,922 | 8,803 | 8,803 | 5,282 | 916.9 |
How the torque is worked out
T = K × F × d
T is the tightening torque (Nm), K the nut factor for the thread condition, F the target clamp load (N) and d the nominal diameter (m). Clamp load is a percentage of the bolt’s proof load: proof stress × tensile stress area.
Friction is the big unknown. The same torque on a dry and an oiled bolt gives very different clamp loads, so pick the thread condition carefully and use the manufacturer’s figure where one exists.
More free tools
Cylinder and tank volume calculator
Litres and m³ for round, horizontal and rectangular tanks, pipe and hoppers, full or part full.
Open tool →Cable sizingCable size calculator
Motor circuits by kW or hp, or any circuit by amps. Worked from first principles, with a PDF summary.
Open tool → All toolsEvery calculator and chart
Tank and pipe volumes, cable sizing, bolt torque and flange tightening in one place.
See all →Common questions
What torque for an M16 10.9 bolt?
About 281 Nm lightly oiled for 75% of proof load.
Does lubrication change bolt torque?
Yes, a lot. Lubricant lowers friction, so the same clamp load needs less torque. Using a dry-bolt torque on an oiled bolt can overload and stretch it.
Need bolting on site? Speak with our mechanical team.